Nzs 3604 Roof Framing

Constructing Timber Outriggers Branz Build

Constructing Timber Outriggers Branz Build

Rafter Fixings Branz Build

Rafter Fixings Branz Build

Veranda Rafter Fixings Branz Build

Veranda Rafter Fixings Branz Build

Loaded Dimension A Guide Branz Build

Loaded Dimension A Guide Branz Build

Roof Form And Framing Original Details Branz Renovate

Roof Form And Framing Original Details Branz Renovate

Securing Buildings Against Uplift Branz Build

Securing Buildings Against Uplift Branz Build

Securing Buildings Against Uplift Branz Build

Builders architects engineers designers and students will find it useful.

Nzs 3604 roof framing.

Nzs 3604 1999 incorporating amendment no. You can follow nzs 3604 for structure and e2 as1 for the roof and wall claddings. 10 1 11 the building envelope wall and roof claddings. Nzs 3604 is used to design most homes and other low rise timber framed buildings in new zealand.

In the previous version of nzs 3604 purlin tables provided for extra fixings around roof edges and ridges reflecting the greater wind uplift in these areas. Nzs 3604 2011 includes provisions for their use. It s therefore important that the industry is clear on the limits and fixing requirements for cantilever verges see figure 1. Very little area was often left as the body of the roof and it proved unrealistic to expect designers and installers to determine when and where extra fixings were required.

The standard is also an important teaching resource for tertiary and trade training organisations. Print timber framed buildings. The 2011 revision of nzs 3604 allowed an increase in the maximum verge cantilever distance from 600 mm to 750 mm and also introduced an addi tional higher wind zone eh. The rafter span is 3 000 m and because this is a light roof the far right column of nzs 3604 2011 table 10 1 rafters for all wind zones see figure 2 can be used for rafter spacings at 1200 mm see note 4 in table 10 1.

It provides methods and details that are used to design many nz timber framed houses and small buildings including many residential decks. Nzs 3604 is a core resource for building consent authorities determining compliance with the nzbc and gives guidance to builders and others involved in the construction of light timber framed buildings. Previous versions of nzs 3604 put most of the emphasis on close coupled roof framing design and construction and left nail plated roof trusses to the realm of specific engineering design. 1 and 2 new zealand standard timber framed buildings superseding nzs 3604 1990 and nzmp 3600 part 1 1992.

Finding fixing requirements for rafters in couple close roof construction is fairly straightforward in nzs 3604 2011 section 10 roof framing. Nzs 3604 is new zealand s most sought after standard. However finding the requirements for rafter fixings in skillion roofs or for hip and valley rafters is a little more circuitous. It is aligned with as nzs 1170 structural design actions and is referenced in acceptable solution for building code clause e2 external moisture e2 as1.